In many locations from chemistry laboratories to industrial facilities, to be able to ensure the safety of life and property towards a attainable hearth hazard, extinguishing techniques are used along with detection and alarm techniques. It can be extraordinarily necessary that the extinguishing techniques put in can be triggered by the fire extinguishing control panel, in order to get rid of a attainable fire with early intervention.
In order to satisfy these needs, and with 35 years of sectoral knowledge and expertise, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel working in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant performance of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be began manually and remotely; and
to ensure that the extinguishing process can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount technology and are geared toward making the automation of the extinguishing system and hearth and gasoline detection system good.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by always considering the wants of the set up. In cases that require the combination of the extinguishing system with the clever addressable fireplace detection system, it offers options via the monitoring modules that even have a ‘supervised’ option.
Supervised monitoring modules play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or quick circuit within the wiring between the contact monitoring modules and the peripheral techniques may cause disruption of the triggering, with potentially important penalties. For this reason, when selecting monitoring modules, it ought to be taken under consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable fire detection and alarm management panels are continually speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to observe situations similar to open circuits and quick circuits which will occur in the system. Many duties could be performed in the hearth extinguishing installation, such because the management and monitoring of all valves that can interrupt the circulate of water, water move alarm switches, stress switch, and electrical or diesel hearth pumps.
By adding Light monitoring modules to 2 separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to control errors and the other to manage the fireplace scenario, monitoring and control of the extinguishing system through an clever addressable fireplace detection and alarm system can be performed successfully.
For more information, go to www.mavili.com.tr/en